Product Details

C/W - 600G

C/W - 600G

6 Channel Ecg Electrocardiograph

Features

Adopt 7" high resolution colour LCD operated by touch screen and function buttons convenient to use.

Sync collection for 12 lead ECG support routine 12 lead and cabrera lead wave form display get high quality ECG waveform via AC filter, EMG filter and low pass filter of ECG signal.

Display 3/6/12-lead ECG waveform print mode, sensitivity paper speed, filter, status etc. on one screen convenient for contrastively diagnosing.

Power supply :AC/DC (which can adapt AC 50/60Hz), with built-in-rechargeable lithium battery charging

circuit, perfect over-current and over-voltage protection circuit. Rhythm lead can be selected freely convenient to observe abnormal heart rhythm.

The subject's clinical information such as (id, name, age, sex, height, weight etc) can be entered. 1000 cases (3s cse is frequently use) can be stored by the built-in-memory convenient for case review and statistics.

In optimal DC state up to 10 hours stand by time continuous print for more than 3 hours and print upto 1000 ECG waveform (3 s case is frequently used).

Multi language (Chinese, English, Turkish, Partuguese, German, Russia, Kazakh etc) interface and

report.

External printer and USB storage device can be connected. Wider in input dynamic range higher in CMRR and polarizing voltage.

 

E6 Technical parameters Performance

Input way: Floating and defibrillation protection

Lead: Standard 12 leads

Patient leakage current: <10µA Input impedance: ≥100 MQ(1Hz)

Frequency response: 0.01Hz-300 Hz(-3dB)

Time constant: ≥3.2s

CMRR: >123 dB

Filter: AC Filter(AC50/60 Hz), EMG Filter (25 Hz/35 Hz (-3 dB)), DFT Filter, Low-pass Filter

Recording way. Thermal printing system

Specification of recording paper: 110 mm(W) x 20 m(L) high-speed thermal paper

Time base selection (paper speed): 5 mn/s, 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, 100 mm/s,

error: ±5% within 0.2s~2.0s Gain control(sensitivity): 2.5、5、10、20、40、10/5, 20/10 mm/mV, accuracy is ±5%; Standard sensitivity: 10 mm/mV±0.2 mm/mV

Auto record: record setup according to auto record forinat and mode, automatically change leads, automatically measure and analyze.

Rhythm record: record setup according to rhythm record format and mode, automatically measure and

analyze. Manual record: record according to manual record format.

Measurement parameters: HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTC interval,

P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1) amplitude

Product safety type: Class I type CF defibrillation-proof applied part

Polarization resistance voltage: 950 mV

Noise level: ≤12 µVp-p

ECG signal input sampling frequency: 32 kHz

Waveform data processing sampling frequency: 1 kHz

Sampling precision: 24-bit

The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal sigral can be detected

Pacing detection channel: all leads

Accuracy of input signal: ±5% Amplitude quantization: ≤5µV/LSB

Interchannel time deviation: <100 us

Power supply:

DC: 7.4V/5000mAh rechargeable lithium battery

AC: 100V-240V(50/60Hz)

Degree of protection against ingress of liquid: IPXO

Working mode: continuous working


Request Quote