Venus
Easy access to view the historical data
Masimo SET SpO2
Measure-through Motion and Low Perfusion pulse oximetry delivers accurate and reliable oxygenation.
Masimo Gas Technology
IRMA Mainstream & ISA Sidestream Analyzers Allows selection of the modality best suited to the application.
Bispectrial Index™ by Aspect
Monitor the level of consciousness of the patient under general anesthesia or sedation. provides BIS, SQL, EMG, SR, SEF, TP, PC value and EEG wave.
NMT
Neuromuscular monitoring
IBP
2-4 Channel, support IBP waveform overlapping display
C.O.
Cardiac Output
Features
15.6"/18.5"High resulotion TFT LCD Touch screen
10 waveform display up to 12-lead ECG analysis
Powerful calculation (Hemodynamic, Dose, Oxygenation, Ventilation)
MEWS(Modified Early Warning Score)
Pacemaker detection
ST & arrhythmia analysis(26 types)
SpO2 support PVI and PI, low perfusion 0.2%
Night mode, standby mode, venipucture mode
Trolley/wall mount braket solutions
Support BIS module, NMT module
Wired/Wireless/4G connection, support HL7 protocol to HIS
SpO2 pulse-tone modulation (Pitch Tone)
VGA/HDMI support external display
Graphical & tabular trend review
Rechargeable Lithium-ion Battery
72 hours full disclosure wave review for each patient
Central Monitoring System
Up to 64 beds Net work is compatible to wired or wireless CMS Auto adaptable to different screen resolution
Specifications
Physical Specifications
Display
15.6" TFT Touch screen
Resolution: 1366 x 768
Number of traces: 10 up to 12 ECG waveforms
Dimension: 398-302-183mm(WHD
Weight: 7 kg under standard configuration LAN 1 standard 8145 port
WLAN IEEE 802.11b/g/
USB 2 USB nectors
HDMI 1 HDM monitor connector
Output connector for Nurse call Defib Sy Analog Output
NIBP
Measurement method: Automatic oscillometric method
Operating mode Manual, automatic, continuous
Measurement unit: mmHg/kPa selectable Typical measurement time: 20-40%
Measurement type: Systolic, Diastolic Mean
Measurement range (mmHg)
Masimo ISA Sidestream CO2 (Optional
Warm-up time: Full accuracy within 10 seconds
Sampling flow rate: 50ml/min(+/-10/min
Measurement Range: 0-25%
Accuracy:
0-15% (0.2% of the reading)
15-25% unspecified
Rise time: 200ms typical at 50ml/min flow rate
Total response time:
within 3 seconds (with 2 m Momaline sampling line
AWRR Range: 0-150bpm
AWRR Accuracy ±1 breath
ECG
Lead type :3-lead 5-lead 12-lead(optional)
ECG waveform2 channels, 7 channels, 12 channels
Display sensitivity(wave gain): 1.25mm/mV(0.125), 2.5mm/mV (0.25), 5mm/mV (0.5% 10mm/mV (1.01, 20mm/mV (2.0), 40mm/mV (40)
Auto
Wave sweep speed: 3.125mm/s, 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Bandwidth
Diagnostic mode: 0.05Hz-150Hz
Monitor mode: 0.5Hz-40Hz
Surgery mode: 0.5Hz-25Hz
Strong filter mode: SHz-25Hz
CMRR-1000E
Notch: 50/60Hz notch filter can be set to on or off
Differential input impedance>SMD
Electrode polarization voltage range 400mV
HR range: 15-350 bpm
Baseline recovery time is after defibrillation in monitor and surgery mode)
Calibration signal1mV (peak peak), accuracy ±3%
Request Quote
If you have any query about this product, feel free to contact us!